Merck 106277 Sodium arsenite solution c(NaAsO₂) 0.05 mol/l (0,1 N) Titripur 1 Lt
Katalog No: 106277.1000
Marka: Merck
- Bir değerlendirme yazın
3.465,60 ₺
Vergi dahil
2-7 Gün içinde teslim edilir.
Merck 106277 Sodium arsenite solution c(NaAsO₂) = 0.05 mol/l (0,1 N) Titripur® Reag. USP
CAS #: 7784-46-5
Grade: Reag. USP
Güvenlik Politikası
KVKK kapsamında kişisel bilgileriniz korumamız altında.
Teslimat politikası
Hızlı ve Güvenli Teslimat.
İade politikası
15 gün iade garantisi.
Merck 106277 Sodium arsenite solution c(NaAsO₂) = 0.05 mol/l (0,1 N) Titripur® Reag. USP
Temel Özellikler Tablosu
CAS # | Kalite Değeri |
---|---|
7784-46-5 | Reag. USP |
Açıklama | |
---|---|
Katalog Numarası | 106277 |
Ürün Bilgisi | |
---|---|
CAS Numarası | 7784-46-5 |
Grade | Reag. USP |
HS Kodu | 3822 90 00 |
Quality Level | MQ200 |
Fizikokimyasal Bilgiler | |
---|---|
Yoğunluk | 1.005 g/m3 (20 °C) |
pH Değeri | 9.3 (H₂O, 20 °C) |
Özellikler | |
---|---|
Volumetric solution in accordance to the chapter reagents of the Pharmacopoeia (USP). | |
Form | liquid |
Amount-of-substance concentration | 0.04975 - 0.05025 |
Measurement uncertainty | +/- 0.00015 |
Traceability | NIST SRM |
Accreditation: This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025. The concentration is determined by volumetric titration and refers to 20°C. The amount-of-substance concentration of this volumetric solution is determined with standardized iodine solution (article number 1.09099). The iodine solution is standardized by sodium thiosulfate solution (article number 1.09147) which has been standardized against volumetric standard potassium iodate (article number 1.02404). This volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 136 potassium dichromate) by means of volumetric standard potassium iodate (article number 1.02404), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%. Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals. |