Merck 109164 Hanus solution for determination of iodine number c(IBr) 0.1 mol/l Titripur 1 Lt

Katalog No: 109164.1000

Marka: Merck

6.292,80 ₺
Vergi dahil 2-7 Gün içinde teslim edilir.

Merck 109164 Hanus solution for determination of iodine number c(IBr) = 0.1 mol/l Titripur®

Synonyms: Iodine solution acc. to Hanus

Adet
Stoktaki son ürünler

  Güvenlik Politikası

KVKK kapsamında kişisel bilgileriniz korumamız altında.

  Teslimat politikası

Hızlı ve Güvenli Teslimat.

  İade politikası

15 gün iade garantisi.

Merck 109164 Hanus solution for determination of iodine number c(IBr) = 0.1 mol/l Titripur®

 

 

Açıklama
Katalog Numarası109164
Eş anlamlıIodine solution acc. to Hanus

 

Ürün Bilgisi
HS Kodu3822 19 00
Quality LevelMQ200

 

Fizikokimyasal Bilgiler
Yoğunluk1.06 g/cm3 (20 °C)
Parlama Noktası40 °C
pH Değeri<1 (H₂O, 20 °C)

 

Özellikler
Formliquid
Amount-of-substance concentration0.0994 - 0.1006
Measurement uncertainty+/- 0.0004
TraceabilityNIST SRM
Accreditation: This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to
DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized sodium thiosulfate solution (article number 1.09147). The sodium thiosulfate solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 136 potassium dichromate) by means of volumetric standard potassium iodate (article number 1.02404), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
109164.1000